Informace o publikaci

Catalytic Signal of Rabbit Liver Metallothionein on a Mercury Electrode:A Combination of Derivative Chronopotentiometry with Adsorptive Transfer Stripping

Autoři

TRNKOVÁ Libuše KIZEK René VACEK Jan

Rok publikování 2002
Druh Článek v odborném periodiku
Časopis / Zdroj Bioelectrochemistry
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
Obor Elektrochemie
Klíčová slova Metallothionein;Chronopotentiometric stripping analysis;Adsorptive transfer stripping;Peak H;Catalytic hydrogen evolution;Effect of aeration
Popis Constant current chronopotentiometric stripping analysis (CPSA) in combination with adsorptive transfer stripping (AdTS) technique was used to study the rabbit liver metallothionein (MT) on a hanging mercury drop electrode (HMDE). Metallothionein yielded a distinct, sharp chronopotentiometric signal at very negative potentials (about -1.7 V ), also known as the "peak H". The height and potential of this peak were dependent on experimental conditions, such as buffer composition, pH, and the presence oxygen in solutions. The peak H was highest in borate buffer with pH close to the isoelectric point (pI) of MT. The chronopotentiometric results contribute to a deeper understanding of the nature of catalytic hydrogen evolution and demonstrate the usefulness of the peak H in peptide and protein research.