Publication details

Verification of positive streamer mechanism for negative corona Trichel pulses in O-2/H-2 mixtures

Authors

KÚDELČÍK Jozef ZAHORANOVÁ Anna HALANDA Juraj ČERNÁK Mirko

Year of publication 2014
Type Article in Periodical
Magazine / Source JOURNAL OF ELECTROSTATICS
MU Faculty or unit

Faculty of Science

Citation
Web Full Text
Doi http://dx.doi.org/10.1016/j.elstat.2014.07.002
Keywords Corona discharges; Streamer; Ionization coefficients
Description Current waveforms of the first negative corona pulses have been measured in O-2 + H-2 mixtures at a pressure range from 27 kPa to 50 kPa. It was observed that the hydrogen admixtures less than 4% do not change significantly the pulse current waveforms. Effects of changing cathode secondary electron emission were studied using a copper cathode coated by Cut and graphite. The results obtained support the theory of the cathode-directed streamer formation during the negative corona pulse rise.