Senzitivita a specificita spektrálního OCT u pacientů s počínajícím glaukomovým onemocněním

Title in English SENSITIVITY AND SPECIFICITY OF SPECTRAL OCT IN PATIENTS WITH EARLY GLAUCOMA
Authors

BOČKOVÁ Magdaléna VESELÝ Petr SYNEK Svatopluk HANÁK Lubomír BENEŠ Pavel

Year of publication 2019
Type Article in Periodical
Magazine / Source Česká a slovenská oftalmologie
MU Faculty or unit

Faculty of Medicine

Citation
web http://www.cs-ophthalmology.cz/cs/journal/2019/5/3
Keywords RNFL analysis; glaucoma; spectral OCT; sensitivity; specificity
Description This work deals with sensitivity and specificity in spectral OCT in detection of early glaucoma. Our goal was to evaluate data from RNFL analysis and compare them with resulted diagnosis of glaucoma neuropathy based on visual field changes. This retrospective study contains 31 subjects who undergone OCT examination in our department between years 2008 and 2017. Test statistic showed RNFL OCT sensitivity 63.64 % and specificity 90 %. Test ROC (receiver operating characteristic curve) showed AUC (area under curve) 0.734, which was statistically significant (p = 0.0097). We found that spectral OCT SLO with RNFL analysis is useful and effective instrument in analysis of glaucoma.