Publication details

Electrocardiographic parameters of left ventricular hypertrophy and prediction of mortality in hemodialysis patients

Authors

BRAUNISCH M. C. GUNDEL P. WERFEL S. MAYER C. C. BAUER A. HALLER B. GUNTHNER R. LORENZ G. ANGERMANN S. MATSCHKAL J. SCHALLER C. HOLZMANN-LITTIG C. KEMMNER S. MANN J. KRIETER A. RENDERS L. WASSERTHEURER S. SCHMIDT G. HEEMANN U. MALÍK Marek SCHMADERER C.

Year of publication 2022
Type Article in Periodical
Magazine / Source JOURNAL OF NEPHROLOGY
MU Faculty or unit

Faculty of Medicine

Citation
web https://link.springer.com/content/pdf/10.1007/s40620-021-01068-0.pdf
Doi http://dx.doi.org/10.1007/s40620-021-01068-0
Keywords Left ventricular hypertrophy; Peguero-Lo presti; Cardiovascular mortality; Hemodialysis
Description Background In hemodialysis patients, left ventricular hypertrophy (LVH) contributes to high cardiovascular mortality. We examined cardiovascular mortality prediction by the recently proposed Peguero-Lo Presti voltage since it identifies more patients with electrocardiographic (ECG) LVH than Cornell or Sokolow-Lyon voltages. Methods A total of 308 patients on hemodialysis underwent 24 h ECG recordings. LVH parameters were measured before and after dialysis. The primary endpoint of cardiovascular mortality was recorded during a median 3-year follow up. Risk prediction was assessed by Cox regression, both unadjusted and adjusted for the Charlson Comorbidity Index and the Cardiovascular Mortality Risk Score. Results The Peguero-Lo Presti voltage identified with 21% the most patients with positive LVH criteria. All voltages significantly increased during dialysis. Factors such as ultrafiltration rate, Kt/V, body mass index, sex, and phosphate were the most relevant for these changes. During follow-up, 26 cardiovascular deaths occurred. Post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages were independently associated with cardiovascular mortality in unadjusted and adjusted analysis. The Sokolow-Lyon voltage was not significantly associated with mortality. An optimal cut-off for the prediction of cardiovascular mortality was estimated at 1.38 mV for the Peguero-Lo Presti. Conclusions The post-dialysis Peguero-Lo Presti cut-off as well as the Peguero-Lo Presti and Cornell voltages allowed independent risk prediction of cardiovascular mortality in hemodialysis patients. Measuring the ECG LVH parameters after dialysis might allow a standardized interpretation as dialysis-specific factors influence the voltages.Y

You are running an old browser version. We recommend updating your browser to its latest version.

More info