Publication details

Mechanical complications and infection control comparison of custom-made and prefabricated articular hip spacers in the treatment of periprosthetic infection

Authors

EMMER Jan TOMÁŠ Tomáš APOSTOLOPOULOS Vasileios BRANČÍK Pavel RAPI Jakub NACHTNEBL Luboš

Year of publication 2023
Type Article in Periodical
Magazine / Source JOINT DISEASES AND RELATED SURGERY
MU Faculty or unit

Faculty of Medicine

Citation
web https://www.sciencedirect.com/science/article/pii/S0169260722002164?via%3Dihub
Doi http://dx.doi.org/10.52312/jdrs.2023.1155
Keywords Custom-made articular hip spacer; periprosthetic joint infection; prefabricated hip spacer
Description Objectives: The purpose of our study was to compare the complication rate and the outcomes of custom-made spacers (C-spacers) and prefabricated articular spacers ( P-spacers) in the treatment of periprosthetic infection. Patients and methods: In this retrospective study, 78 patients (44 females, 34 males; mean age: 68.5 +/- 9.48 years; range, 47 to 82 years) with articular spacers implanted in our institution were analyzed between January 2009 and December 2019. We recorded implant results as per mechanical complications, infection control, the interval from surgery to definitive hip replacement, and the rate of achieving recovery of joint function after stage two arthroplasty. Results: There were 29 revised spacers; 18 of them were C-spacers and 11 were P-spacers (p= 0.0383). A total of 16 dislocations were recorded, of which six were dislocations of C-spacers, and 10 were dislocations of P- spacers (p= 0.0082). Additionally, we registered four spacer breakages, all of which occurred in C-spacers (p= 0.295). C-spacers failed early, at an mean interval of 2.2 weeks after implantation, and P- spacers failed later, with an mean of 9.3 weeks after implantation (p=0.0187). A total of nine reinfection complications of spacers were registered; only one infection of P-spacers, and eight infections related to C-spacers ( p= 0.2583). Definitive revision total hip arthroplasty (rTHA) after spacer explantation and successful treatment of the infection occurred in 63 cases out of 78 patients. Definitive rTHA occurred after the use of C-spacers in 41 (78%) patients and after the use of C- spacers in 22 (84%) patients (p=0.7816). C-spacers had a mean interval from spacer implantation to definitive rTHA of 6.56 +/- 6.03 months, and P-spacers had a mean interval of 4 +/- 1.93 months (p= 0.0164). Conclusion: Custom-made spacers were shown to have lower mechanical complication rates than prefabricated ones but more infection complications. Prefabricated spacers had more dislocations and fewer breakages. Custom-made spacer mechanical failures occurred earlier compared to prefabricated ones.

You are running an old browser version. We recommend updating your browser to its latest version.

More info