You are here:
Publication details
Výsledky implantací endokapsulárních distančních prstenců
Title in English | Results of Implantations of Endocapsular Distance Rings |
---|---|
Authors | |
Year of publication | 2000 |
Type | Article in Periodical |
MU Faculty or unit | |
Citation | |
Field | ORL, ophthalmology, stomatology |
Keywords | endocapsular distance ring;extraction of subluxated cataract; dialysis of the zonula |
Description | Endocapsular distance ring increases possibilities of extraction subluxated cataract. Its importance consistsof stabilisation of capsular bag and with the possibility of implantation posterior intraocular lens. In the group there are 20 patients with implantated 21 distance rings. The period of follow up was 4 - 24 months. We used of a polymethylmethacrylate distance ring from firms Erilens, Morcher and IOLTechnology. Indication for the implantation of a distance ring was dialysis less than 2 quadrants, it depends on size and type of distance ring. The authors evaluate complications during the operation and early and later results after operation. |