You are here:
Publication details
On Simulating 3D Fluorescent Microscope Images
Authors | |
---|---|
Year of publication | 2007 |
Type | Article in Proceedings |
Conference | Computer Analysis of Images and Patterns |
MU Faculty or unit | |
Citation | |
Web | http://dx.doi.org/10.1007/978-3-540-74272-2_39 |
Field | Use of computers, robotics and its application |
Keywords | synthetic image; simulator; procedural texture; convolution; fluorescent optical microscope |
Description | In recent years many various biomedical image segmentation methods have appeared. Though typically presented to be successful the majority of them was not properly tested against ground truth images. The obvious way of testing the quality of new segmentation was based on visual inspection by a specialist in the given field. The novel 3D biomedical image data simulator is presented in this paper. It offers the results of high quality. The evaluation of generated synthetic data is compared against real image data using standard similarity techniques. |
Related projects: |