Publication details

Metody analýzy endoteliální mikroskopie

Title in English The Methods of Analysis of the Endothelial Microscopy
Authors

LOUKOTOVÁ Věra HLINOMAZOVÁ Zuzana HORÁČKOVÁ Monika VLKOVÁ Eva

Year of publication 2007
Type Article in Periodical
Magazine / Source Česká a Slovenská oftalmologie
MU Faculty or unit

Faculty of Medicine

Citation
Field ORL, ophthalmology, stomatology
Keywords endothelium; specular microscopy; cells density; hexagonality;
Description Aim: To compare results of classical and digital analysis of the corneal endothelium. Material and methods: We evaluated a group of 36 eyes with physiological findings of the anterior segment of the eye; the average age of examined persons was 32.8 years . The examination was performed by means of non contact specular microscope SP 1000 TOPCON. The obtained finding was evaluated by means of i) classical analysis, ii) automatic digital analysis, and iii) revised digital analysis. The result of the classical analysis is the cellular density (number of cells/mm2). The digital analysis is made possible by means of the connection of the specular microscope with the computer program IMAGENET. The Endothelial Analysis System evaluates furthermore the coefficient of the cellular area variation (%), and the hexagonality (%). The normality of the values distribution was evaluated by means of the test Liliefors, subsequently the paired t test or nonparametric Wilcoxons test were used. Results: Comparing results of the automatic to the revised digital analysis, statistically significant difference in all evaluated parameters was found (P = 0.01). The average cells density calculated by means of classical analysis is by 3 % smaller than the value established by means of revised digital analysis . Regardless of that, no statistically evident difference was found at the 1 % level of significance. In 13 cases the revised digital analysis showed lower values than the classical one, whereas in 23 cases the overestimation by revised digital analysis up to 501 cells/mm2 was found. To complete the classical analysis or the automatic digital analysis, it takes in average 7 minutes. The time needed to examine one sample of endothelium using the revised digital analysis was in the examined group 30 minutes. Conclusion: Although there is no statistically significant difference (P = 0.01) between the revised digital analysis and the classical analysis, and between both methods there is statistically significant dependence (r = 0.82); it is necessary to consider their incomplete compatibility in case of results interpretation in a single patient. The revised digital analysis is rather more time consuming, but supplies more information about the status of the endothelial single layer.

You are running an old browser version. We recommend updating your browser to its latest version.

More info