Title in English | The Use of Brain Tissue Oxymetry in Patients After SAH |
---|---|
Authors | |
Year of publication | 2008 |
Type | Article in Periodical |
Magazine / Source | Česká a Slovenská Neurologie a Neurochirurgie |
MU Faculty or unit | |
Citation | |
Field | Neurology, neurosurgery, neurosciences |
Keywords | brain tissue oxymetry; SAH |
Description | Good outcome is associated with PbtO2 values > 20 mmHg, while poor outcome is associated with PbtO2 values < 20 mmHg in the long-term post-SAH period. Our current observations show that brain tissue oxymetry might be advantageous in the early detection of ischemic changes both peri- and postoperatively. |