Zde se nacházíte:
Informace o publikaci
The effect of biological shielding on fast neutron and photon transport in the VVER-1000 mock-up model placed in the LR-0 reactor
Autoři | |
---|---|
Rok publikování | 2013 |
Druh | Článek v odborném periodiku |
Časopis / Zdroj | Applied Radiation and Isotopes |
Fakulta / Pracoviště MU | |
Citace | |
Doi | http://dx.doi.org/10.1016/j.apradiso.2013.01.034 |
Obor | Jaderná energetika |
Klíčová slova | LR-0; VVER-1000 mock-up; Neutron spectroscopy; Biological shielding |
Popis | The paper is intended to show the effect of a biological shielding simulator on fast neutron and photon transport in its vicinity. The fast neutron and photon fluxes were measured by means of scintillation spectroscopy using a 45×45 mm2 and a 10×10 mm2 cylindrical stilbene detector. The neutron spectrum was measured in the range of 0.6–10 MeV and the photon spectrum in 0.2–9 MeV. The results of the experiment are compared with calculations. The calculations were performed with various nuclear data libraries. |