Simultaneous determination of reduced and oxidized glutathione in tissues by a novel liquid chromatography-mass spectrometry method: application in an inhalation study of Cd nanoparticles

Logo poskytovatele
Autoři

BLÁHOVÁ Lucie KOHOUTEK Jiří LEBEDOVÁ Jana BLÁHA Luděk VECERA Z. BUCHTOVA M. MÍŠEK Ivan HILSCHEROVÁ Klára

Rok publikování 2014
Druh Článek v odborném periodiku
Časopis / Zdroj Analytical and Bioanalytical chemistry
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
Doi http://dx.doi.org/10.1007/s00216-014-8033-z
Obor Vliv životního prostředí na zdraví
Klíčová slova Glutathione; LC MS/MS; Tissues; Oxidative stress; Nanoparticle; Cadmium oxide
Popis The paper presents the development of an advanced extraction and fast analytical LC MS/MS method for simultaneous analyses of reduced and oxidized glutathione (GSH and GSSG, respectively) in different animal tissues. The simultaneous determination of GSH and GSSG is crucial because the amount and ratio of both GSH and GSSG may be altered in response to oxidative stress, an important mechanism of toxicity. The method uses the derivatization of free thiol groups in GSH. Its performance was demonstrated for less explored tissues (lung, brain, and liver) in mouse. The combined extraction and analytical method has very low variability and good reproducibility, maximum coefficients of variance for within-run and between-run analyses under 8 %, and low limits of quantification; for GSH and GSSG, these were 0.2 nM (0.06 ng/mL) and 10 nM (6 ng/mL), respectively. The performance of the method was further demonstrated in a model experiment addressing changes in GSH and GSSG concentrations in lung of mice exposed to CdO nanoparticles during acute 72 h and chronic 13-week exposures. Inhalation exposure led to increased GSH concentrations in lung. GSSG levels were in general not affected; nonsignificant suppression occurred only after the longer 13-week period of exposure. The developed method for the sensitive detection of both GSH and GSSG in very low tissue mass enables these parameters to be studied in cases where only a little sample is available, i.e. in small organisms or in small amounts of tissue.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info