A multicentre study on unattended automated office blood pressure measurement in treated hypertensive patients

Autoři

FILIPOVSKÝ Jan SEIDLEROVÁ Jitka CERAL Jiří VYSOČANOVÁ Petra ŠPÁC Jiří SOUČEK Miroslav ŘIHÁČEK Ivan MATEŘÁNKOVÁ Markéta KÖNIG Petr ROSOLOVÁ Hana

Rok publikování 2018
Druh Článek v odborném periodiku
Časopis / Zdroj Blood Pressure
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
Doi http://dx.doi.org/10.1080/08037051.2018.1425606
Klíčová slova Automated blood pressure; ambulatory blood pressure monitoring; attended blood pressure; BPTru device; blood pressure measurement
Popis Aims: Unattended automated office blood pressure (uAutoOBP) may eliminate white-coat effect. In the present study, we studied its relationships to attended office blood pressure (BP) and ambulatory BP monitoring (ABPM).Material and methods: Stable treated hypertensive subjects were examined in four Czech academic hypertension centres. uAutoOBP was measured with the BP Tru device; attended BP was measured six times: three times with auscultatory method (AuscOBP) by the physician followed optionally by three oscillometric measurements (OscOBP). ABPM was performed within one week from the clinical visit.Results: Data on 172 subjects aged 63.712.4 years with AuscOBP 127.6 +/- 12.1/77.6 +/- 10.0mm Hg are reported. uAutoOBP was by 8.5 +/- 9.0/3.0 +/- 6.1mm Hg lower than AuscOBP. The AuscOBP-uAutoOBP difference increased with the AuscOBP level and it did not depend on any other factor. OscOBP differed by 8.6 +/- 8.6/1.9 +/- 5.7mm Hg from uAutoOBP. 24-hour mean BP was by 4.2 +/- 12.1/3.5 +/- 7.8mm Hg lower than AuscOBP and by 4.3 +/- 11.0/0.5 +/- 6.9mm Hg higher than uAutoOBP; the correlation coefficients of 24-hour mean BP with AuscOBP and with uAutoOBP did not differ (p for difference.13). In the lowest BP group (systolic AuscOBP<120mm Hg or diastolic AuscOBP<70mm Hg), both AuscOBP and uAutoOBP were lower than 24-hour mean BP, while in the highest BP group (systolic AuscOBP140mm Hg or diastolic AuscOBP90mm Hg), they were higher.Conclusions: Compared to uAutoOBP, attended BP measurement gives higher values, both when measured with auscultatory or oscillometric method. Inter-individual variability of AutoOBP - uAuscOBP difference, as well of uAutoOBP - ABPM difference, is large. We did not prove that uAutoOBP would be associated to 24-hour ambulatory BP more closely than attended BP.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info