Informace o publikaci

Interrater Agreement and Detection Accuracy for Medium-Vessel Occlusions Using Single-Phase and Multiphase CT Angiography

Autoři

OSPEL J. M. BALA F. MCDONOUGH R. V. VOLNÝ Ondřej KASHANI N. QIU W.. MENON B. K. GOYAL M.

Rok publikování 2022
Druh Článek v odborném periodiku
Časopis / Zdroj American Journal of Neuroradiology
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
www http://www.ajnr.org/content/early/2021/11/25/ajnr.A7361
Doi http://dx.doi.org/10.3174/ajnr.A7361
Klíčová slova Medium-Vessel Occlusions; Single-Phase and Multiphase CT Angiography
Popis BACKGROUND AND PURPOSE: Accurate and reliable detection of medium-vessel occlusions is important to establish the diagnosis of acute ischemic stroke and initiate appropriate treatment with intravenous thrombolysis or endovascular thrombectomy. However, medium-vessel occlusions are often challenging to detect, especially for unexperienced readers. We aimed to evaluate the accuracy and interrater agreement of the detection of medium-vessel occlusions using single-phase and multiphase CTA. MATERIALS AND METHODS: Single-phase and multiphase CTA of 120 patients with acute ischemic stroke (20 with no occlusion, 44 with large-vessel occlusion, and 56 with medium-vessel occlusion in the anterior and posterior circulation) were assessed by 3 readers with varying levels of experience (session 1: single-phase CTA; session 2: multiphase CTA). Interrater agreement for occlusion type (large-vessel occlusion versus medium-vessel occlusion versus no occlusion) and for detailed occlusion sites was calculated using the Fleiss ? with 95% confidence intervals. Accuracy for the detection of medium-vessel occlusions was calculated for each reader using classification tables. RESULTS: Interrater agreement for occlusion type was moderate for single-phase CTA (? ?=?0.58; 95% CI, 0.56?0.62) and almost perfect for multiphase CTA (? = 0.81; 95% CI, 0.78?0.83). Interrater agreement for detailed occlusion sites was moderate for single-phase CTA (? = 0.55; 95% CI, 0.53?0.56) and substantial for multiphase CTA (? = 0.71; 95% CI, 0.67?0.74). On single-phase CTA, readers 1, 2, and 3 classified 33/56 (59%), 34/56 (61%), and 32/56 (57%) correctly as medium-vessel occlusions. On multiphase CTA, 48/56 (86%), 50/56 (89%), and 50/56 (89%) medium-vessel occlusions were classified correctly. CONCLUSIONS: Interrater agreement for medium-vessel occlusions is moderate when using single-phase CTA and almost perfect with multiphase CTA. Detection accuracy is substantially higher with multiphase CTA compared with single-phase CTA, suggesting that multiphase CTA might be a valuable tool for assessment of medium-vessel occlusion stroke.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info