Harmonized Quality Assurance/Quality Control Provisions for Nontargeted Measurement of Urinary Pesticide Biomarkers in the HBM4EU Multisite SPECIMEn Study

Logo poskytovatele
Logo poskytovatele
Logo poskytovatele
Logo poskytovatele
Autoři

VITALE Chiara Maria LOMMEN Arjen HUBER Carolin WAGNER Kevin BORJA Garlito Molina NIJSSEN Rosalie PRICE Elliott James BLOKLAND Marco FREDERIKE van Tricht MOL Hans G J KRAUSS Martin DEBRAUWER Laurent PARDO Olga LEON Nuria KLÁNOVÁ Jana ANTIGNAC Jean-Philippe

Rok publikování 2022
Druh Článek v odborném periodiku
Časopis / Zdroj Analytical chemistry
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www https://pubs.acs.org/doi/10.1021/acs.analchem.2c00061
Doi http://dx.doi.org/10.1021/acs.analchem.2c00061
Klíčová slova Anatomy; Extraction; Mass spectrometry; Quality management; Solvents
Popis A set of quality assurance/quality control (QA/QC) criteria for nontargeted measurement of pesticide exposure markers in a large-scale study of human urine has been proposed and applied across five laboratories within the HBM4EU project. Quality control material, including reference standards and fortified pooled urine samples (QC urine) were prepared in a centralized way and distributed across participants to monitor analytical performance and consistency of the liquid chromatography coupled to high-resolution mass spectrometry data generated with a harmonized workflow. Signal intensities, mass accuracy, and retention times of selected QA/QC markers covering a broad range of physicochemical properties were monitored across QC solvent standards, QC urine samples, study urine samples, and procedural blanks, setting acceptance thresholds for repeatability and accuracy. Overall, results showed high repeatability of the collected data. The RSDs of the signal intensities were typically below 20-30% in QC and study samples, with good stability of the chromatographic separation (retention time drift within 2-4 s intrabatch and 5 s interbatch) and excellent mass accuracy (average error < 2 ppm). The use of the proposed criteria allowed for the identification of handling errors, instrumental issues, and potential batch effects. This is the first elaboration of harmonized QA/QC criteria applied across multiple laboratories to assess the quality of data generated by nontargeted analysis of human samples.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info