Informace o publikaci

Measurement of dosimetrical cross sections with 14.05 MeV neutrons from compact neutron generator

Autoři

KOŠŤÁL Michal CZAKOJ Tomáš ALEXA Petr ŠIMON Jan ZMEŠKAL Marek SCHULC Martin KRECHLEROVÁ Alena PELTÁN Tomáš MRAVEC Filip CVACHOVEC František RYPAR Vojtěch UHLÁŘ Radim HARKUT Ondřej MATĚJ Zdeněk

Rok publikování 2023
Druh Článek v odborném periodiku
Časopis / Zdroj ANNALS OF NUCLEAR ENERGY
Fakulta / Pracoviště MU

Fakulta informatiky

Citace
www https://www.sciencedirect.com/science/article/pii/S0306454923002232?via%3Dihub
Doi http://dx.doi.org/10.1016/j.anucene.2023.109904
Klíčová slova Cross section measurement; D-T generator; Neutron dosimetry; Sample irradiation
Popis This paper deals with the measurement of the differential dosimetry cross sections using a small compact D-T neutron generator with 14.05 ± 0.08 MeV neutron emission (1 × 108 n/s into 4?). In spite of low neutron flux, it is possible to get measurable gamma-ray activities by irradiating a larger amount of target material placed in close geometry. The experimentally determined cross sections are in good agreement with the cross sections in the IRDFF-II dosimetry library. The comparison with other nuclear data libraries was performed as well. It is worth noting that the mean standard deviation in IRDFF-II library is about 4 %, while in the case of other data libraries they are from 5.5 % to 7.5 %. This result can be understood as a validation of IRDFF-II using 14.05 MeV neutrons and also a confirmation of the applicability of small compact generators in the measurement of activation cross sections.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info