Informace o publikaci

The learning curve of robot-assisted laparoscopic aortofemoral bypass grafting for aortoiliac occlusive disease

Autoři

NOVOTNÝ Tomáš DVOŘÁK Martin STAFFA Robert

Rok publikování 2011
Druh Článek v odborném periodiku
Časopis / Zdroj Journal of Vascular Surgery
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
Doi http://dx.doi.org/10.1016/j.jvs.2010.09.007
Obor Chirurgie včetně transplantologie
Klíčová slova Robot-assisted vascular surgery; Aortoiliac occlusive disease; Learning curve
Popis Background: Our objective was to assess the learning curve of robot-assisted laparoscopic aortofemoral bypass grafting in a group of 40 patients. Methods: Learning curve estimations were used for anastomosis, clamping, and operative time assessment. For conversion rate evaluation the cumulative summation (CUSUM) technique was used. Results: We created 21 aortofemoral and 19 aortobifemoral bypasses. The median proximal anastomosis time was 23 minutes, clamping time 60 minutes and operative time 295 minutes. Secondary patency was 100%. Data showed a typical short learning curve for robotic proximal anastomosis. The operative time learning curve confirmed the procedure’s complexity. Acceptable conversion rate set at 5% was achieved. Conclusions: Anastomosis creation, one of the main difficulties of laparoscopic bypass grafting, has been overcome. The endoscopic dissection of the aortoiliac segment remains the most difficult part of the operation.

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.