In-line Bragg magnifier based on V-shaped germanium crystals

Autoři

VAGOVIČ P. KORYTÁR D. MIKULÍK Petr CECILIA A. FERRARI C. YANG Y. HANSCHKE D. HAMANN E. PELLICCIA D. LAFFORD T.A. FIEDERLE M. BAUMBACH T.

Rok publikování 2011
Druh Článek v odborném periodiku
Časopis / Zdroj Journal of Synchrotron Radiation
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www http://scripts.iucr.org/cgi-bin/paper?mo5017
Doi http://dx.doi.org/10.1107/S090904951102989X
Obor Fyzika pevných látek a magnetismus
Klíčová slova x-ray optics; x-ray diffraction; monochromators
Popis In this work an X-ray imaging system based on a recently developed in-line two-dimensional Bragg magnifier composed of two monolithic V-shaped crystals made of dislocation-free germanium is presented. The channel-cut crystals were used in one-dimensional and in two-dimensional (crossed) configurations in imaging applications and allowed measurement of phase-contrast radiograms both in the edge-enhanced and in the holographic regimes. The measurement of the phase gradient in two orthogonal directions is demonstrated. The effective pixel size attained was 0.17 um in the one-dimensional configuration and 0.5 um in the two-dimensional setting, offering a twofold improvement in spatial resolution over devices based on silicon. These results show the potential for applying Bragg magnifiers to imaging soft matter at high resolution with reduced dose owing to the higher efficiency of Ge compared with Si.
Související projekty: