Publication details

Mechanical Restitution in Left and Right Guinea Pig Ventricular Preparations

Authors

NOVÁKOVÁ Marie NOVÁKOVÁ Zuzana MOUDR Jiří

Year of publication 2002
Type Article in Periodical
Magazine / Source Scripta medica
MU Faculty or unit

Faculty of Medicine

Citation
Field Physiology
Keywords Mechanical restitution; papillary muscle; heart; left and right ventricles; guinea pig
Description The study was focused on identification of possible differences in the onset and time course of mechanical restitution in guinea pig multicellular heart preparations, i.e., papillary muscles from the right and left ventricles. Stimulated twitches of both preparations mounted in a horizontal perfusion bath were recorded simultaneously. Mechanical restitution curves were constructed at 25C and 35C and at stimulation rates of 0.5 Hz, 1 Hz and 2 Hz. No statistically significant differences in restitution curves of both preparations were found. It can be concluded that, in the assessment of mechanical behaviour of the heart, the guinea pig left ventricular papillary muscle appears to be a suitable substitute for the conventionally employed right ventricular papillary muscles.

You are running an old browser version. We recommend updating your browser to its latest version.