Publication details

Užití tahových šroubů k fixaci zlomenin kloubního výběžku dolní čelisti

Title in English Application o lag screws for fixation of mandibular condylar fractures
Authors

MACHÁLKA Milan

Year of publication 2003
Type Article in Periodical
Magazine / Source Česká stomatologie
MU Faculty or unit

Faculty of Medicine

Citation
Field ORL, ophthalmology, stomatology
Keywords facial bone fractures; mandibular condyle; articular process of the mandible; osteosynthesis
Description Displaced and luxation fractures of the mandibular condyle require surgical reposition and fixation under direct sight supervision. Application of lag screws from the Eckelt-Martin instrumentation set has proved successful in treatment of 15 patient. No considerable complications occurred. The mandible is fully functional during the time of healing. An intermaxillary fixation, which is uncomfortable for the patient, is not necessary to be done. Though, it is necessary to remove the screw subsequently by another surgical operation. Complete instrumentation set is necessery to be available for the choice of the described method.